ISC Dual Channel Isolated Signal Conditioner/Converter

ISC Dual Channel Isolated Signal Conditioner/Converter
Product Detailed
Related Categories:Fiber Optic Equipment
Feature: Programmable for various input signals and measuring ranges. Configurable without Power Connected. Din Rail Mo

The  Din Rail converter is user configurable using our   software on your PC/notebook or our dedicated handheld programmer. The easy to use software is available free from your supplier or can be downloaded from our web site and should be used in conjunction with the URC-1020 USB cable which incorporates an interface converter necessary for communications.The ISC converter can be configured without any loop or power connected making it easy to configure in the workshop before installation.

 
 
 
Specification:
  
 
Input Thermocouple (T/C) : industry standard thermocouple types J, K, T, E, B, R, S, N, C (ITS-90).
Pt100: Excitation 180uA. 2 or 3 wire connection (ITS-90 α =0.00385).
Voltage: -60mVdc to 60mVdc or –10Vdc to 10Vdc.
Current : 0-24mAdc
Accuracy Refer to Table 1 Input Signal
A/D Resolution 16 bits
Input Sampling Rate <200ms
Power Supply DC 24V
OutputCurrent Output: 4~20mA( Resistive load 600Ω max.)
Continuous Voltage Output: 0~50mV; 0~10V…( Resistive load 600Ω min.)
Output Resolution 0.6 μ A(15 bits)
Output Response Time <200ms
Common Mode Rejection Ratio(CMRR) >80dB
Electromagnetic Compatibility (EMC) En 50081-2, En 50082-2
Galvanic isolation 3.75 KV. between input and output
Operating Temperature -40 to 85 ° C
Humidity0 to 90% RH
Dimension75mm(W)x87mm(H)x18.5mm(D)
 
Table 1 Input Signal
Input signal Maximum Range Accuracy
Thermocouple J -50 to 1000 ° C (-58 to 1832 ° F )1 ° C
Thermocouple K -50 to 1370 ° C (-58 to 2498 ° F )± 1 ° C
Thermocouple T -270 to 400 ° C (-454 to 752 ° F )± 1 ° C
Thermocouple E -50 to 700°C (-58 to 1292°F)± 1 ° C
Thermocouple B 0 to 1750 ° C (32 to 3182 ° F )± 2 ° C (Note1)
Thermocouple R -50 to 1750 ° C (-58 to 3182 ° F )± 2 ° C
Thermocouple S -50 to 1750 ° C (-58 to 3182 ° F )± 2 ° C
Thermocouple N -50 to 1300 ° C (-58 to 2372 ° F )± 2 ° C
Thermocouple C -50 to 1800 ° C (-58 to 3272 ° F )± 2 ° C
Pt100 -200 to 600 ° C (-328 to 1112 ° F )± 0.2 ° C
mV -60mVto 60mV± 0.01m V
Voltage (Note2)-10 to 10Vdc± 1m V
Current (Note2)0 to 24mAdc± 10μA
 
Note 1 : Accuracy is not guaranteed between 0 and 400°C (0 and 752°F) for type B. Note 2 : The internal DIP switch should be set.
 
 